GE MULTILINK ML1200 User Manual

Page 132

Advertising
background image

7–8

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

ACCESS USING RADIUS

CHAPTER 7: ACCESS USING RADIUS

Setting port control parameters (continued)

ML1200(auth)##

reauth port=1 status=enable period=300

Successfully set re-authentication parameter(s)

ML1200(auth)##

shoW-port reauth

Port

Reauth Status

Reauth Period (sec.)

=========================================

1

Enabled

300

2

Enabled

3600

3

Enabled

3600

4

Enabled

3600

5

Enabled

3600

6

Enabled

3600

ML1200(auth)##

show-stats port=3

Port 3 Authentication Counters

authEntersConnecting

: 3

authEapLogoffsWhileConnecting

: 0

authEntersAuthenticating

: 3

authAuthSuccessesWhileAuthenticating

: 2

authAuthTimeoutsWhileAuthenticating

: 0

authAuthFailWhileAuthenticating

: 0

authAuthReauthsWhileAuthenticating

: 0

authAuthEapStartsWhileAuthenticating

: 1

authAuthEapLogoffWhileAuthenticating

: 0

authAuthReauthsWhileAuthenticated

: 0

authAuthEapStartsWhileAuthenticated

: 0

authAuthEapLogoffWhileAuthenticated

: 0

backendResponses

: 5

backendAccessChallenges

: 2

backendOtherRequestsToSupplicant

: 0

backendNonNakResponsesFromSupplicant

: 2

backendAuthSuccesses

: 2

backendAuthFails

: 0

ML1200(auth)##

trigger-reauth port=3

Successfully triggered re-authentication

ML1200(auth)##

This command forces the
authentication period on port #1
every 5 minutes; all other ports are
force authenticated every hour as
indicated by the

show-port reauth

command below.

Advertising