2 flow control, 3 back pressure, Ontrol – GE MULTILINK ML1200 User Manual

Page 151: Ressure

Advertising
background image

CHAPTER 9: PORT MIRRORING AND SETUP

PORT MIRRORING AND SETUP

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

9–5

9.3.2

Flow Control

The

flow

setting is disabled by default. In this case, the port will not generate flow control

packets and drops received flow control packets. If the

flow

setting is enabled, the port

uses 802.3x Link Layer Flow Control, generates flow control packets, and processes
received flow control packets.

Note

With the port speed set to auto (the default) and flow control set to enabled; the switch
negotiates flow control on the indicated port. If the port speed is not set to auto, or if flow
control is disabled on the port, then flow control is not used.

Use the

flowcontrol

command to set flow control:

flowcontrol xonlimit=<value> xofflimit=<value>

where

xonlimit

can be from 3 to 127 (default value is 4) and

xofflimit

ranges from 3 to

127 (default value is 6).

9.3.3

Back Pressure

The

backpressure

command disables/enables back pressure based flow control

mechanisms. The default state is disabled. When enabled, the port uses 802.3 Layer 2 back
off algorithms. Back pressure based congestion control is possible only on half-duplex, 10-
Mbps Ethernet ports. Other technologies are not supported on the MultiLink ML1200
Managed Field Switch.

backpressure rxthreshold=<value>

where the

rxthreshold

value can be from 4 to 30 (default is 28).

Back pressure and flow control are used in networks where all devices and switches can
participate in the flow control and back pressure recognition. In most networks, these
techniques are not used as not all devices can participate in the flow control methods and
notifications. Alternately, QoS and other techniques are widely used today.

In the example below, the MultiLink ML1200 Managed Field Switch is set up with flow
control and back pressure.

Example 9-2: Back pressure and flow control

ML1200#

device

ML1200(device)##

show flowcontrol

XOnLimit : 4

XOffLimit : 6

ML1200(device)##

flowcontrol xonlimit=10 xofflimit=15

XOn Limit set successfully

XOff Limit set successfully

ML1200(device)##

show flowcontrol

XOnLimit : 10

XOffLimit : 15

ML1200(device)##

show backpressure

Rx Buffer Threshold : 28

(continued on next page)

Advertising