CHAPTER 5: IP ADDRESSING

IP ADDRESSING

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

5–9

ML1200#

show sysconfig

System Name: ML1200

System Contact: [email protected]

System Location: Markham, Ontario

Boot Mode: manual

Inactivity Timeout(min): 120

Address Age Interval(min): 300

Inbound Telnet Enabled: Yes

Web Agent Enabled: Yes

Time Zone: GMT-05hours:00minutes

Day Light Time Rule: Canada

System UpTime: 7 Days 12 Hours 30 Mins 46

Secs

ML1200#

System variables can be changed. Below is a list of system variables which GE
recommends changing.

System Name

: Using a unique name helps you to identify individual devices in a

network.

System Contact

and

System Information

: This is helpful for identifying the

administrator responsible for the switch and for identifying the locations of
individual switches.

To set these variables, change the mode to be SNMP configuration mode from the
manager mode using the following syntax

snmp
setvar
[sysname|syscontact|syslocation] =<string>

The following command sequence sets the system name, system location and system
contact information.

ML1200#

snmp

ML1200(snmp)##

setvar ?

setvar: Configures system name, contact or

location

Usage: setvar

[sysname|syscontact|syslocation]=<string>

ML1200(snmp)##

setvar syslocation=Fremont

System variable(s) set successfully

ML1200(snmp)##

exit

ML1200#

5.3.3

Date and Time

It may be necessary to set the day, time or the time zone manually. This can be done by
using the

set

command with the necessary date and time options with the following

syntax:

set timezone GMT=[+ or -] hour=<0-14>
min=<0-59>
set date year=<2001-2035> month=<1-12> day=<1-31>
[format=<mmddyyyy|ddmmyyyy|yyyymmdd>]
set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm]