To set the SNTP server to be 3.94.210.5 (with a time out of 3 seconds and a number of
retries set to 3 times); allowing the synchronization to be ever 5 hours, the following
sequence of commands are used

ML1200#

sntp

ML1200(sntp)##

setsntp server=3.94.210.5 timeout=3 retry=3

SNTP server is added to SNTP server

database

ML1200(sntp)##

sync hour=5

ML1200(sntp)##

sntp enable

SNTP is already enabled.

ML1200(sntp)##

exit

ML1200(sntp)#

SNTP parameters can be configured through the EnerVista Secure Web Management
software with the Configuration > SNTP menu item. The SNTP menu allows the time zone