GE MULTILINK ML1200 User Manual

Page 190

Advertising
background image

11–4

MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL

VLAN REGISTRATION OVER GARP

CHAPTER 11: VLAN REGISTRATION OVER GARP

• Send VLAN advertisements, and also receive advertisements for VLANs on other

ports and dynamically join those VLANs

• Send VLAN advertisements, but ignore advertisements received from other ports
• Avoid GVRP participation by not sending advertisements and dropping any

advertisements received from other devices

The

show-vlan

command displays a switch's current GVRP configuration, including the

unknown VLANs.

show-vlan

A port must be enabled and configured to learn for it to be assigned to the dynamic VLAN.
To send advertisements, one or more tagged or untagged static VLANs must be configured
on one (or more) switches with GVRP enabled. The ML1200 software allows a dynamic
VLAN to be converted to a static VLAN with the

static

command.

static vlan=<VID>

Note

The

show vlan type=tag

command will display VID in case the VID is not known.

Example 11-1 illustrates how to convert a dynamic VLAN into a static VLAN.

As the following table indicates, a port that has a tagged or untagged static VLAN has the
option for both generating advertisements and dynamically joining other VLANs.

Table 11–1: Port settings for GVRP operations

Unknown

VLAN mode

Operations

Learn

Enables the port to dynamically join any VLAN

for which it receives and advertisement, and

allows the port to forward the advertisement it

receives.

Block

Prevents the port from dynamically joining a

VLAN that is not statically configured on the

switch. The port will still forward advertisements

that were received by the switch on other ports.

Block should typically be used on ports in

insecure networks where there is exposure to

attack - such as ports where intruders can

connect.

Disable

Causes the port to ignore and drop all the

advertisements it receives from any source.