34 a2327: on or off expected, 35 a2328: value is truncated, A2327: on or off expected – Motorola HC12 User Manual

Page 275: A2328: value is truncated

Advertising
background image

Assembler Messages

Message Codes

MCUez HC12 Assembler

User’s Manual

MOTOROLA

Assembler Messages

275

12.3.34 A2327: ON or OFF Expected

Type:

Error

Description:

The syntax for an MLIST or CLIST directive is not correct.
These directives expect a unique operand, which take the value
ON or OFF.

Example:

CodeSec: SECTION

CLIST

Tip:

Specify either ON or OFF after the MLIST or CLIST directive.

Example:

CodeSec: SECTION

CLIST ON

12.3.35 A2328: Value is Truncated

Type:

Warning

Description:

The size of one of the constants listed in a DC directive is
bigger than the size specified in the DC directive.

Example:

DataSec: SECTION
cst1: DC.B $56, $784, $FF
cst2: DC.w $56, $784, $FF5634

Tip:

Reduce the value of the constant to the size specified in the DC
directive.

Example:

DataSec: SECTION
cst1: DC.B $56, $7, $84, $FF
cst2: DC.W $56, $784, $FF, $5634