Rouble, Hooting – Microtek MiniLink User Manual

Page 23

Advertising
background image

T

ROUBLE

S

HOOTING

PROBLEM SUGGESTION

No Link Activity

1. NO POWER – make certain both WEMs have power and

the red Power LED is on. Make sure the connected
Ethernet/IP device is powered.

2. Check the configuration of all WEMs. Each pair and/or all

groups of WEMs setup to communicate with each other
must be set to the same channel. If you have changed any
of the advanced settings, make sure the configurations of all
WEMs being used in the system are the same.

3. Make sure the cable run between the WEM and Ethernet

device is no longer than 300 feet.

4. Make sure the cables being used are straight through and all

cable connectors are attached properly.

5. If using an Ethernet hub or fast switch, try a crossover cable

between the hub and the Power Injector Module.

No Signal Level LED or
Flashing Signal Level
LED

1. Check line-of-sight of the WEMs. Verify the WEMs are

aimed properly. You should have clear, wide-open line of
sight between the WEM modules.

2. Change channels; cycle power.
3. Verify sufficient voltage into each PIM.

Note: The Host AP WEM green signal level LED will flash indicating
the number of Client SU WEMs it is communicating with. This is
normal for this device and should not be confused as lack of signal
strength. The green LED on the Client SU WEM should be solid if
the Client SU is communicating with the Host AP at a full 20Mbps
(50+ Mbps – super mode).

All three solid LEDs but
no picture or picture
drops out after a period
of time

1. Check video at the camera
2. Check wiring into encoders or decoders
3. Try changing channels; cycle power. An uninterruptible

power supply (UPS) may be required and is suggested.

4. Connect one WEM directly into a PC or laptop and verify

that the IP address is accessible. Check the other WEM(s)
the same way, then verify that each IP address is accessible
over the wireless link into a PC/laptop.

5. Verify the connected Ethernet/IP device is configured

correctly.

No Green Signal Level
LED (When Using the
MLWES-30 with two
18” Parabolic Dishes)

1. Verify wide-open line-of-sight

2. Re-angle your dish antenna in a downward angle until both

LEDs are solid green.

3. Mount the dishes higher above ground level and/or above

any obstruction.

If you have tried the trouble shooting steps above and the system is still not working correctly, please
contact MicroTek at 888-366-4276, Monday through Friday, between the hours of 8:00AM and
5:00PM Pacific Time. One of our technicians will work with you to rectify the problem over the
phone.

Thank you,

MicroTek Electronics, Inc.

- 20 -

Advertising