4-1. Specifications

Specification

Description

Overall Dimensions

Height: 10 in (254 mm); Width: 14-1/2 in (368 mm); Depth: 16 in (406 mm)

Weight

Net: IH/TS (no recorder) 13.1 lb (5.9 kg); IH/TS (digital recorder) 21.1 lb (9.6 kg)

Type Of Input Power

24 Volts DC, 115 Volts AC

Memory Capacity

One Program Up To 8 Segments

Control Capacity

Single Power Source Control

Operating Temperature Range

41

°

To 104

°

F (5

°

To 40

°

C)

Storage Temperature Range

−4

°

To 122

°

F (−20

°

To 50

°

C)

Reference the controller and recorder manuals for additional information.

Ref. 802 905-A / 802 900

4-2. IH/TS Installation

1

1

Tools Needed:

3/8, 5/16 in

Y Turn Off and disconnect

input power.

5 kW System
1. Temperature

Control/Recorder

2. 5kW Mounting Bracket
3. Screw, 10-32 (4)
Install and secure IH/TS to mount-

ing bracket using supplied #10

screws.
4. 5kW Power Source Case
5. Case Sheet Metal Screw (4)
Remove case sheet metal screws

from both top left and right sides of

unit. Install mounting bracket to

power source and secure by rein-

stalling sheet metal screws.
25 kW System
6. 25 kW Power Source Case
7. Rear Mounting Bracket
8. Screw, 1/4-20 (2)
Remove front and middle mounting

screws from top of Item 6 case. Lo-

cate IH/TS and reinstall front

mounting screws. Locate rear

mounting bracket, and secure with

supplied 1/4-20 screws. Reinstall

middle mounting screws to secure

bracket to case.

3

4

6

2

8

8

7

5

4

Advertising
This manual is related to the following products:

TS