3-5. recovering from an interruption – Miller Electric IH User Manual

Page 35

Advertising
background image

OM-203 185 Page 31

6-3-5.

Recovering From An Interruption

Press the “RUN” button to start profile.

There are two conditions the controller looks at to determine:

1) If it should supply output power and

2) If the power source contactor should be on.

1) If the current temperature is more than 105 F above the target temperature in

segment 1, the IH/TS will not require output from the power source. The blue

Heat On light will be on and power source will not provide output. (Providing the

Panel/Remote switch on the power source is in the remote position.)

2) If the current temperature is more than 255 F above the target temperature in

segment 1, the blue Heat On light will be off and the system will not provide

power. (Regardless of Panel/Remote switch position.)

NOTE

To continue from the current part temperature, rather than waiting for the part temperature to fall to within 10

°

of

segment 1’s target temperature:

Press the “HOLD” button − The controller displays “HOLD”.

Press

“Page” button until “ProG LiSt” appears on the display.

Press

“Scroll” button to SEG 1’s TGT temperature setting.

Use

Y

or

B

“Up” or “Down” button to adjust target temp to the current

temperature of +5

°

F.

Press

“Page” button until parameter screen appears on the display.

Press “RUN” button to resume program − the controller will step to the new target

temperature setting and continue through the remainder of the profile.

Y Keep all panels, doors, and

covers closed and secure

during programming.

1. 2408 Controller
2. Page Forward Button
3. Scroll Button
4. Run/Hold Indicator
5. Down Button
6. Up Button
7. Actual Temperature
8. Setpoint Temperature
9. Heat On Pilot Light
10. Fault/ Limit Light
11. Run Button
12. Hold Button
13. Stop Button

1

2

AUTO

MAN

RUN

HOLD

B

Y

3

4

5

200.0

200.0

OP1

SP2

7

8

9

10

6

11

12

13

Advertising
This manual is related to the following products:

TS