2 displaying and saving system parameters – MRV Communications EM316-2SFP User Manual

Page 35

Advertising
background image

EM316-2SFP User Guide


P/N 1259003-001 Rev C3

26

4.4.5.2 Displaying and Saving System Parameters


Use the write terminal command to display the current operating parameters.



Use the write file command to save the current parameters to the configuration file.

fiberdriver(port/1.1.1)# write terminal
Building configuration...

Current configuration:
!
! Configuration saved on 2005/01/01 01:54:11
!
! Configuration written by admin!
!
! EM316LNXNM-OT v4.0 fdr 52 (May 14 2007 - 13:35:38).
! U-Boot 1.0.1 (Jan 25 2005 - 11:08:25).
! Linux kernel v2.4.26 (#1 Wed Dec 13 10:36:44 PST 2006).
! EM316LNXNM (firmware 5c.13) (00:20:1a:02:53:8f).
! Copyright (c) MRV Corp. 1993-2007.
!
ip interface 192.168.14.201/24
username admin password encrypted
$1$kQ2rIq/$Ob8wFa2EW135XC4TnN7wJ/
class super username admin group all
group all write 2
group all write 1
snmp-server community read encrypted
$1$hZyZkA1$xiJTxyGDfVb1bcAYyW9Wi1
snmp-server community write encrypted
$1$wZCHI9/$6H3mce5Y15iLhtdpoXBoa1
chassis 1 type NC316BU-16 rev 1
slot 1.1 type EM316-2SFP rev 1
slot 1.2 type EM316LNXNM-OT rev 4
fiberdriver(port/1.1.1)#

fiberdriver(port/1.1.1)# write file
Building configuration file...
OK, saved to startup-config
fiberdriver(port/1.1.1)#

Advertising