16 diagnostic download, Diagnostic download, Figure 68 - csv download – Motorola PTP 400 Series User Manual

Page 134

Advertising
background image

132

The diagnostic plotter displays all of the data from the cascaded Histograms 1, 2 and 3. It

uses a bespoke x-axis with a compressed timeline so that resolution is not sacrificed. The

most recent data is shown to the right, and the oldest data to the left.

The most recent hour's worth of data from Histogram 1 is displayed between 0 minutes (0m)

and 60 minutes (60m) to the right of the x-axis; Data for the previous 24 hours from

Histogram 2 is displayed between 60 minutes (60m) and 25 hours (25h) in the middle of the

x-axis; Data for the previous 30 days from Histogram 3 is displayed between 25 hours (25h)

and 31 days (31d) to the left of the x-axis.

The Trace selection allows the user to control which traces are plotted.

As with other management pages the page refresh period can be used to interactively

monitor the wireless link.

8.3.16 Diagnostic Download

The diagnostics Download page allows the system administrator to download snapshots of

system diagnostics.

Figure 68 - CSV Download

The following diagnostics are available:

• Vector

Error

• Rx

Power

• Tx

Power

• Signal Strength Ratio V/H
• Link

Loss

• Rx Data Rate
• Tx Data Rate
• Aggregate Data Rate
• Receive

SNR

• Rx

Gain

Advertising