2 post-power testing, Post-power testing – Motorola PTP 400 Series User Manual

Page 154

Advertising
background image

152

CAT-5

Length

meters

Resistance

pins 4-7

ohms

Resistance

pins 8-5

ohms

0 0.0 2.3

10 1.7 4.0

20 3.4 5.7

30 5.1 7.4

40 6.8 9.1

50 8.5 10.8

60 10.2 12.5

70 11.9 14.2

80 13.6 15.9

90 15.3 17.6

100 17.0 19.3

Table 18 - Resistance Table Referenced To The RJ45 At The PIDU Plus

11.3.2 Post-Power Testing

1 Connect the RJ45 to the PIDU and apply power. The power LED should be illuminated

continuously. If the power LED does not illuminate unplug the ODU connection from the

PIDU and check the power LED illumination. If the power LED still does not light then

check the power source.

2 The Ethernet LED should be observed starting with 10 slow flashes, 30 seconds after

powering. This confirms that the ODU has the correct power connections, if the Ethernet

LED does not light check the wiring to pins 4 & 5 and 7 & 8.

3 If a computer, switch or router is connected to the LAN side of the PIDU Plus then the

Ethernet LED should flash with network activity. If the Ethernet LED does not show

Ethernet activity then the network equipment and the Ethernet cables need to be

checked, specifically continuity through to the ODU of pins 1 & 2 and 3 & 6.