4 emc immunity compliance – europe only, Emc immunity compliance – europe only – Motorola PTP 400 Series User Manual

Page 205

Advertising
background image

203

18.4 EMC Immunity Compliance – Europe Only

Top-level Specification ETSI 301-489.

Specification

Comment

EN 55082-1 Generic EMC and EMI
requirements for Europe

EN 61000-4-2: 1995 Electro Static
Discharge (ESD), Class 2, 8 kV air, 4 kV
contact discharge

EN 61000-4-3: 1995 ENV50140: 1993
(radiated immunity) 3 V/m

EN 61000-4-4: 1995 (Bursts/Transients),
Class 4, 4 kV level (power lines AC & DC)

Signal lines @ 0.5 kV open circuit voltage.

EN 6100045:1995, (Surge Immunity)

Requires screened connection to users
network

EN 61000-4-6: 1996 (Injected RF), power
line, Class 3 @ 10 V/m

Signal lines, Class 3 @ 3 V RMS un-
modulated.

Advertising