3.3.4 Remote LEDs and Recovery Switch

The PTP 400 Series Bridge PIDU Plus provides a facility to connect remote LEDs and

Recovery switch allowing the PIDU Plus to be mounted inside an enclosure. At the left end of

the PIDU Plus under the ODU connection cover can be found three jumpers and a PCB

header. Jumpers J906 and J907 should be removed and connection to the remote LEDs and

Recovery switch made to J908 as shown in Figure 9.

J905

J907

J906

J908

ODU

Connection

J905

J907

J906

J908

Remove links J906 and J907

Yellow Ethernet LED

Green Power LED

Recovery Switch

Figure 9 - Remote LED and Recovery Switch Wiring

3.3.5 Cables and Connectors

The cable used to connect the PTP 400 Series PIDU Plus to the ODU can be any standard

CAT 5 type provided that it is suitable for outdoor deployment. Motorola recommends that

cables to the specification below be used.

NEC/CEC: CMR (ETL) C (ETL) 75C SUN RES OIL RES II

Failure to use the recommended (or equivalent) standard of cable may invalidate the

system’s safety certification.

The PIDU Plus/ODU cable may be unscreened (UTP) or screened (STP). However,

unscreened cables reduce the system’s ability to cope with nearby lightning strikes. If

lightning activity is common in the area of deployment, the use of screened cable is highly

recommended. See Section 11Lightning Protection”.