Monessen Hearth TPB18 User Manual

Page 11

Advertising
background image

70D0004

11

16"

42"

CLEARANCES

and

HEIGHT REQUIREMENTS

Sidewall and ceiling clearances: The sides of the fireplace opening must be at least 16" from any combustible wall. The
ceiling must be at least 42" from the top of the fireplace opening.

Figure 4 - Sidewall and Ceiling Clearances

The dimensions shown in Figures 4 through 12 and defined in the fireplace manufacturer's
instructions are minimum clearances to maintain when installing this heater. Left and
right clearances are determined when facing the front of the heater.
When heater is installed into a ventless firebox, minimum clearances, as specified by
the ventless firebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.

W

ARNING