Floor clearance – Monessen Hearth TPB18 User Manual

Page 16

Advertising
background image

16

70D0004

Heater in

Fireplace or

Firebox

1

3

/

8

" Minimum

Combustible

Material

14" Minimum

Heater in

Fireplace or

Firebox

Combustible

Material

This Distance

May Now Be

Less than 1

3

/

8

"

FLOOR CLEARANCE

The gas log heater must be installed at least 1

3

/

8

" above any combustible flooring material, such as carpeting or

tile, which is closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top
surface of carpeting, tile, etc. see Figure 11.

OR

The gas log heater may be installed nearer to the floor if a minimum of 14" of noncombustible material such as
slate or marble is installed between the base of the fireplace and the combustible flooring. see Figure 12.

Figure 11 - Minimum Clearance above Combustible Flooring

Figure 12 - Minimum Clearance above Combustible Flooring with

Noncombustible Material Installed at Base of Fireplace