Clearances, Height requirements – Monessen Hearth TPB18 User Manual

Page 15

Advertising
background image

70D0004

15

Heater in
Fireplace or
Firebox

Heat
Resistant
Material

10" or less

12" min. 28"

2

1

/

2

"

8"

6"

7"

14

1

/

2

"

4"

Figure 10 - Minimum Mantel Clearance with Hood - TPB24/30

(Example of Unsafe Installation)

Figure 9 - Minimum Mantel Clearance with No Hood — TPB24/30

Example: The bottom of the mantel may project from the wall

a maximum of 10" at a minimum of 28" above the
opening.

CLEARANCES

and

HEIGHT REQUIREMENTS

Figure 10 is an example of an unsafe mantel instal-
lation.
This mantel projects 4" at 8" above the opening,
exceeding the maximum acceptable distance of 2

1

/

2

"

The mantel also projects 7" at 14

1

/

2

" above the opening,

exceeding the maximum acceptable distance of 6".

If your mantel profile is unsafe, you may either:
• Raise the mantel to an acceptable height
OR
• Remove the mantel

Advertising