Appendix h: lamp cartridge replacement, continued, Caution, Warning – MITSUBISHI ELECTRIC WD-52627 User Manual

Page 110: Burn danger

Advertising
background image

110

Appendices

Appendix H: Lamp Cartridge Replacement, continued

1. Turn TV power off and allow lamp to cool at least one

hour before proceeding.

2. Remove the plastic air exhaust grille/cover by

removing two screws with a #2 (large) Phillips
screwdriver. See figure 1.

3. With a large flat-blade screwdriver, completely loosen

the three shiny screws securing the lamp cartridge
until they disengage from the mating threads.
These are captive screws and cannot be removed
completely from the lamp cartridge.

4. Grasp the wire handle of the lamp cartridge and pull

the old cartridge straight out towards you. Note the
orientation of the cartridge. See figures 2 and 3.

5. Do not touch the glass parts of the new lamp

cartridge. Oils from your fingers on the glass could
cause premature failure of the lamp. Insert the new
cartridge into the TV in the same orientation as the
old cartridge. Push on the cartridge housing until it is
fully seated.

8. With either your fingers or the screwdriver, gently

tighten the three screws. If using a screwdriver,
only use two fingers for final tightening. AVOID
OVERTIGHTENING!

9. Replace the plastic grille/cover and retaining screws.
10. This lamp contains mercury. Do not dispose of old

lamp with common trash. For disposal or recycling
information, please contact your local authorities or
the Electronic Industries Alliance at www.eiae.com.

CAUTION

ONLY REPLACE LAMP CARTRIDGE WITH THE SAME

PART NUMBER 915P026010.

WARNING

THE GRILLE/COVER IS PROVIDED WITH AN INTERLOCK
TO REDUCE THE RISK OF EXCESSIVE ULTRAVIOLET
RADIATION. DO NOT DEFEAT ITS PURPOSE OR
ATTEMPT TO SERVICE WITHOUT REMOVING GRILLE/
COVER COMPLETELY.

CAUTION

BURN DANGER!

During normal operation, the surfaces inside

the TV near the lamp are extremely hot.

TOUCH THE LAMP CARTRIDGE BY THE HANDLE ONLY

Do not touch the glass parts of the lamp cartridge.

Figure 2. Removal of lamp cartridge

Figure 1. Removal of the exhaust grille

Handle

Figure 3. Lamp-cartridge handle

To order a new lamp under warranty, call (800) 332-2119. Please have model number,
serial number and TV purchase date available. To order a new lamp after warranty, call
(800) 553-7278 and order lamp part number 915P026010.