Route/connect cables & hand pendant - continued – Maxon Telecom WL7-VERS. C User Manual

Page 32

Advertising
background image

PATENTS PENDING

32

11921 Slauson

A

ve. Santa Fe Springs, CA. 90670 (800) 227-41

16 F

AX (888) 771-7713

HEX

NUT

2 GA

TERMINAL

LUG

FIG. 32-1

4. Cut any excess wire from long power cable.

Strip 1/2” insulation from the cut end and
install 2 GA terminal lug and shrink tubing.
Next, insert the power cable through the
protective cover (FIG. 32-1). Connect the
cable terminal to the terminal stud on the
power input bracket as shown in FIG. 32-
1
. Position the protective cover over the
power cable connection (FIG. 32-1).

5. Route the interlock cable from safety interlock

system on the vehicle, underneath vehicle fl oor
and through the grommet, and up to the Lift (FIG.
32-2)
. If possible, use the same cable routing as
the long power cable installed in previ-
ous steps. Secure the interlock cable
every 8”-10”.

6. Make sure interlock cable will reach

the white-red stripe wire (interlock
signal from vehicle) and the brown
wire (interlock signal to vehicle) on
the Lift (FIG. 32-2). Signal may
be ground or V+. Connect the inter-
lock wires from the vehicle interlock
system to the white-red stripe wire
and brown wire on the Lift (FIG.
32-2)
.

FIG. 32-2

INTERLOCK WIRE

(SIGNAL FROM

VEHICLE)

BROWN WIRE

(FROM LIFT)

WHITE-RED STRIPE

WIRE (FROM LIFT)

INTERLOCK

CABLE

INTERLOCK WIRE

(SIGNAL TO

VEHICLE)

POWER

INPUT

BRACKET

ROUTE/CONNECT CABLES & HAND PENDANT - Continued

LONG

POWER

CABLE

EXTERNAL

TOOTH LOCK

WASHER

TERMINAL

STUD

PROTECTIVE

COVER

Advertising