4. Push the inboard rollstop back

against the lock as if a wheel-
chair is pushing on the rollstop
FIG. 47-1).

5. On the inboard rollstop switch,

loosen screws (1) and (2) one-half
turn (FIG. 47-2B). Next, rotate
switch bracket clockwise until the
switch activates with an audible
“click”. Then tighten screws (1)
and (2) securely.

6. Turn ON power switch on pump

cover (FIG. 47-2A). Then raise
(UP) the platform to fl oor level
(FIG. 46-1). Verify that “INBD
SW”
is not displayed on the lift
controller. If necessary repeat
this procedure.

PLATFORM BELOW FLOOR LEVEL,

WITH IBRS UP (LH SIDE SHOWN)

FIG. 47-1

PLATFORM BELOW FLOOR LEVEL,

WITH IBRS UP (LH SIDE SHOWN)

FIG. 47-2A

CUT-AWAY VIEW OF

LH VERTICAL ARM

& IBRS SWITCH

FIG. 47-2B

SCREW (2)

SWITCH

(REF)

SCREW (1)

SWITCH

BRACKET