Asr/asi logic diagrams, Appendix c – Madrigal Imaging MP-9 User Manual

Page 123

Advertising
background image

Appendix C

ASR/ASI Logic Diagrams

Check the

Input memory of the

currently selected input for

matching H & V scan

frequencies.

match

yes

yes

no match

Change the current

setup memory to the

matched Input memory.

no

Do nothing.

A change in scan frequency is detected.

The change is greater than 100 Hz horizontal

or greater than 1 Hz vertical.

Is ASR

set to On for the

currently selected

input?

no

Switch to the selected

source and/or setup

memory.

A source, Recall memory, or channel was manually

selected. The H & V scan frequencies of the source

do not match that of the selected setup memory.

Is ASR

set to On for the

selected

input?

Search for a

Recall memory with

matching H & V scan

frequencies.

match

match

no match

ASI

Logic

Begins

Change the current

setup memory to the

matched Recall memory.

Search for an

Input memory with

matching H & V scan

frequencies.

match

match

no match

Use the display settings

of the matched Input

memory but do not update

the current setup memory.

Create new display set-

tings by interpolating the

two closest setup mem-

ories (in freq.). Do not

update the setup memory.

ASI

Functions

Adjustments made at

this point are stored

in the current

setup memory.

Adjustments made at this

point are displayed but

NOT stored in the current

setup memory.

ASR Logic Diagram

B.3

Advertising