Configuring relay warning, Configuring relay warning -50 – Moxa Technologies Moxa EtherDevice Switch EDS-508 User Manual

Page 66

Advertising
background image

EDS-508 Series User’s Manual

Featured Functions

3-50

Mail Server IP/Name

Setting

Description

Factory Default

IP address

The IP Address of your email server.

None

Account Name

Setting

Description

Factory Default

Max. 45 Charters

Your email account.

None

Password Setting

Setting

Description

Factory Default

Disable/Enable to
change Password

To reset the Password from the Web
Browser interface, check-mark the Change
password check-box, type the Old
Password, type the New Password, retype
the New password, and then click on
Activate.

Disable

Old Password

Type current password when enabled to
change password; Max. 45 Characters.

None

New Password

Type new password when enabled to
change password.

None

Retype Password

If you type a new password in the
Password field, you will be required to
retype the password in the Retype new
password field before updating the new
password.

None

Email Address

Setting

Description

Factory Default

Max. 30
Characters

You can set up to 4 email addresses to
receive alarm emails from EDS.

None

Send Test Email

After finishing with the email settings, you should first press the “Activate” button to activate
those settings, then press the “Send Test Email” button to verify that the settings are correct.

NOTE

Auto warning e-mail messages will be sent through an authentication protected SMTP server
that supports the CRAM-MD5, LOGIN, and PAIN methods of SASL (Simple Authentication
and Security Layer) authentication mechanism.
We strongly recommend not entering your Account Name and Account Password if auto
warning e-mail messages can be delivered without authentication mechanism.

Configuring Relay Warning

The Auto Relay Warning function uses relay output to alert the user when certain user-configured
events take place. There are three basic steps required to set up the Relay Warning function:

1. Configuring Relay Event Types

Select the desired Event types from the Console or Web Browser Event type page. (A
description of each event type is given later in the Relay Alarm Events setting subsection.)