EDS-508 Series User’s Manual

Featured Functions

3-52

NOTE

The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec) Port Event items are
related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.

Override relay alarm settings

Check-mark the check box to override the relay warning setting temporarily. Releasing the relay
output will allow administrators until the warning condition has been fixed.

Relay Alarm List

Use this table to see if any relay alarms have occurred.

Using Line-Swap-Fast-Recovery

The Line-Swap Fast Recovery function, which is enabled by default, allows MOXA EtherDevice
Switch to return to normal operation extremely quickly after devices are unplugged and then
re-plugged into different ports. The recovery time is on the order of a few milliseconds. Compare
this with standard commercial switches for which the recovery time could be on the order of
several minutes. To disable the Line-Swap Fast Recovery function, or to re-enable the function
after it has already been disabled, access either the Console utility’s Line-Swap recovery page, or
the Web Browser interface’s Line-Swap fast recovery page, as shown below.