Cylinder limitation jumper description, Subsystem configuration, Jumper location / configuration – Maxtor DIAMONDMAX 91536H2 User Manual

Page 14

Advertising
background image

PRODUCT DESCRIPTION

2 – 5

JUMPER CONFIGURATION

J50

J48

J46

J44

J42

Master/Slave
Only drive in single drive system*
Master drive in dual drive system*
Slave drive in dual drive system

C
C
O

Cable Select
Disabled*
Enabled

O
C

Cylinder Limitation
Disabled*
Enabled

O

C

Factory Reserved

O

Factory Reserved

O

Key * = Default C = Closed (jumper installed) O = Open (no jumper installed)

Figure 2-1

PCBA Jumper Location and Configuration

Cylinder Limitation Jumper Description

On some older BIOS', primarily those that auto-configure the disk drive, a hang may occur. The Cylinder
Limitation jumper reduces the capacity in the Identify Drive allowing large capacity drives to work with older
BIOS'. The capacity reported when J46 is closed will be as follows: drives less than or equal to 32GB will
report 2.1GB. Drives greater than 32GB will report 32GB.

Subsystem Configuration

Dual Drive Support

Two drives may be accessed via a common interface cable, using the same range of I/O addresses. The drives
are jumpered as device 0 or 1 (Master/Slave), and are selected by the drive select bit in the
Device/Head register of the task file.

All Task File registers are written in parallel to both drives. The interface processor on each drive decides
whether a command written to it should be executed; this depends on the type of command and which
drive is selected. Only the drive selected executes the command and activates the data bus in response to
host I/O reads; the drive not selected remains inactive.

A master/slave relationship exists between the two drives: device 0 is the master and device 1 the slave.
When J50 is closed (factory default, figure 2-1), the drive assumes the role of master; when open, the drive
acts as a slave. In single drive configurations, J50 must be closed.

Cable Select Option

CSEL (cable select) is an optional feature per ANSI ATA specification. Drives configured in a multiple drive
system are identified by CSEL’s value:

– If CSEL is grounded, then the drive address is 0.
– If CSEL is open, then the drive address is 1.

Jumper Location / Configuration

Darkened jumper pins indicate factory-installed (default) shunts.