HOST SOFTWARE INTERFACE

6 – 5

Control Diagnostic Registers

These I/O port addresses reference three Control/Diagnostic registers:

I/O PORT

R E A D

WRITE

3 F 6 h

Alternate Status

Fixed Disk Control

3 F 7 h

Digital Input

Not used

Alternate Status Register

Contains the same information as the Status register in the Task File. However, this register may be read at
any time without clearing a pending interrupt.

Device Control Register

Contains the software Reset and Enable bit to enable interrupt requests to the host. Bit definitions follow:

7

6

5

4

3

2

1

0

0

0

0

0

0

SRST

IEN

0

Reset

IRQ Enable

Reset – Setting the software Reset bit holds the drive in the reset state. Clearing the bit re-enables the drive.
The software Reset bit must be held active for a minimum of 5 µsec.

IRQ Enable – Setting the Interrupt Request Enable to 0 enables the IRQ 14 signal to the host. When this

bit is set to 1, IRQ14 is tri-stated, and interrupts to the host are disabled. Any pending interrupt occurs when

the bit is set to 0. The default state of this bit after power up is 0 (interrupt enabled).

Digital Input Register

Contains information about the state of the drive. Bit definitions follow:

7

6

5

4

3

2

1

0

x

- W G

-HS3

-HS2

-HS1

-HS0

- D S 1

DS0

Reserved

Write

Gate

Head

Select 3

Head

Select 2

Head

Select 1

Head

Select 0

Drive

Select 1

Drive

Select 0

Bit 7 of the host data bus is not driven when this register is read.

-Write Gate – Reflects the state of the active low write gate signal on the drive.

-Head Select 3 through -Head Select 0 – Represents the ones complement of the currently selected head number.

-Drive Select 1 – Is 0 if drive 1 selected; 1 otherwise.

-Drive Select 0 – Is 0 if drive 0 selected; 1 otherwise.