OM-225 311 Page 16

4-8.

Selecting A Location And Connecting Input Power For 230 VAC Model

Y

Installation must meet all Na-
tional and Local Codes − have
only qualified persons make
this installation.

Y

Disconnect and lockout/tag-
out input power before con-
necting input conductors from
unit.

Y

Always connect green or
green/yellow conductor to
supply grounding terminal
first, and never to a line termi-
nal.

1

Rating Label

Supply correct input power.

2

Black And White Input
Conductor (L1 And L2)

3

Green Or Green/Yellow
Grounding Conductor

4

Input Power Cord.

5

Disconnect Device (switch
shown in the OFF position)

6

Disconnect Device Grounding
Terminal

7

Disconnect Device Line
Terminals

Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.

Connect input conductors L1 and L2
to disconnect device line terminals.

8

Over-Current Protection

Select type and size of over-current
protection using Section 4-9 (fused
disconnect switch shown).

Close and secure door on disconnect
device. Remove lockout/tagout de-
vice, and place switch in the On posi-
tion.

9

Plug (NEMA 6-50P)

10 Receptacle (NEMA 6-50R)

Connect plug to receptacle.

Y

Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.

Ref. 804 681-A / Ref. 802 443 / Ref. 802 085 / 803 766-B

18 in (457 mm) of
space for airflow

L1

L2

230 VAC, 1

10

Y

Do not move or operate unit
where it could tip.

Tools Needed:

5

4

L1

L2

1

=GND/PE Earth

Ground

3

2

6

7

8

1

9

Advertising