14. connecting spool gun to millermatic 140/180 – Miller Electric Millermatic 180 User Manual

Page 25

Advertising
background image

.

A complete Parts List is available on-line at www.MillerWelds.com

OM-225 311 Page 21

4-14. Connecting Spool Gun To Millermatic 140/180

804 984-A / Ref. 801 987

1

Drive Assembly

2

Spool Gun

3

Gun Securing Knob

4

Gun End

Loosen thumbscrew. Insert end
through opening until it bottoms
against drive assembly. Tighten
gun securing knob.

Spool gun must be inserted
completely to prevent leakage of
shielding gas.

5

Gun Trigger Plug

Insert plug into receptacle, and
tighten threaded collar.

6

Spool Gun/MIG Gun Switch

Place switch in Spool Gun position.

7

Polarity Changeover Terminal
Block

To make proper polarity connection,
see welding power source Owner’s
Manual.

Close door.

Incorrect

Gun Fully Seated

Gun Not Seated

6

Correct

.

Be sure that gun end is tight against drive assembly.

4

4

Exposed O-rings

will cause shielding

gas leakage.

5

7