5-5.

Weld Parameter Chart For 115 VAC Model w/Factory Set
Non-Wire Speed Tracking Mode

1. Number on left of

slash is Voltage

Knob Setting.

(Example: 4.5 / 65)

2. Number on right

of slash is Wire

Speed Knob Setting.

(Example: 4.5 / 65)

Refer to chart below to select Voltage and Wire Speed based on
thickness of material being welded.

Solid Wire

ER70S−6

(DCEP)
Solid Wire

ER70S−6

(DCEP)
Flux Core

E71T−11

(DCEN)
Stainless

Steel

(DCEP)

Selecting Wire, Gas and Control Settings for Aluminum

.030” (0.8 mm)
.035” (0.9 mm)

Aluminum w/
Opt. Spool Gun

Aluminum
4043ER

100% Argon