Miller Electric Millermatic 180 User Manual

Page 34

Advertising
background image

.

A complete Parts List is available on-line at www.MillerWelds.com

OM-225 311 Page 30

5-6.

Weld Parameter Chart For 115 VAC Model w/Wire Speed Tracking Mode

1. Number on left of

slash is Voltage

Knob Setting.

(Example: 4.5/65)

2. Number on right

of slash is Wire

Speed Knob Setting.

(Example: 4.5 / 65)

Refer to chart below to select Voltage and Wire Speed based on
thickness of material being welded.

Solid Wire

ER70S−6

(DCEP)
Solid Wire

ER70S−6

(DCEP)
Flux Core

E71T−11

(DCEN)
Stainless

Steel

(DCEP)

To enable wire speed tracking, proceed as follows:

1. Turn Power switch off.

2. Rotate Voltage knob to minimum.

3. Rotate Wire Speed knob to maximum.

4. Hold gun trigger in while turning on Power switch.

.

To verify wire speed tracking is on, open drive roll pressure arm, pull trigger,
and rotate Voltage knob from min. to max. Drive roll speed will change rpm
if tracking is on.