DFX & DBX Series Vent Free Fireplaces

FIREPLACE INSTALLATION

NOTICE: A qualified gas appliance installer must connect the heater to the gas supply.
Consult all local codes.

W

ARNING

Use new black iron or steel pipe. Internally tinned copper or copper
tubing can be used per National Fuel Code, section 2.6.3, providing gas
meets hydrogen sulfide limits, and where permitted by local codes. Gas
piping system must be sized to provide minimum inlet pressure (Listed
on Data Plate) at the maximum flow rate (BTU/hr). Undue pressure loss
will occur if the pipe is too small.
A manual shutoff valve must be installed upstream of the appliance.
Union tee and plugged 1/8" NPT pressure tapping point should be
installed upstream of the appliance. Figure 10
A sediment trap should be installed upstream to prevent moisture and
contaminants from passing through the pipe to appliance controls and
burners. Failure to do so could prevent the appliance from operating
reliable. Figure 11

FP2447
gas connection

3” Min.

To Fireplace

Pipe Coupling

Stainless
Flexible Tube

Pipe

Locations Pressure Tapping
Point Installation

Manual Shutoff
Valve

Gas Supply
Inlet

FP447

Figure 11 -
Gas Connection

Tee Joint

Pipe Nipple

Cap

Sediment
Trap

IMPORTANT: Loosen the pipe adapter on the flex tube before installing to the system
piping.
Always use an external regulator for all propane/LPG heaters only, to reduce the supply
tank pressure to a maximum of 13" w.c. This is in addition to the internal regulator in the
heater valve.

CHECk GAS TYPE: The gas supply must be the same as stated on the
heater’s rating plate. If the gas supply is different, DO NOT INSTALL
THE HEATER. Contact your dealer for the correct model.

W

ARNING