Fp2512 install remote rcvr – Monessen Hearth DFX24C User Manual

Page 16

Advertising
background image

16

33D4047

DFX & DBX Series Vent Free Fireplaces

ELECTRICAL INSTALLATION

CONNECT REMOTE RECEIVER

THESE INSTRUCTIONS SUPERCEDE THE SECTION
ENTITLED “HEARTH MOUNT” IN THE MILLIVOLT
HAND-HELD REMOTE INSTRUCTIONS SUPPLIED
WITH THE REMOTE.
Figure 16
1. Remove bottom louvre door.
. Connect the remote connectors located in the unit.
3. Stick Velcro• pads with self-adhesive backing to bottom

of remote receiver and to floor of compartment behind
access panel.

4. Attach remote receiver to firebox with Velcro• pads.

Control switch must face forward.

NOTE: Do not place remote in combustion chamber.

SKY

TECH

OFF

ON

REM

OTE

FIRE

PLA

CE

RE

MO

TE

FP2512
install remote rcvr

Velcro•

Remote
Receiver

Velcro•

FP51

Figure 16 -
Install Remote Receiver

CHECk SYSTEM OPERATION

The millivolt system and individual components may be checked with a millivolt meter having
a 0-1000 mV range. Conduct each check shown in chart below by connection meter test leads
to terminals as indicated.

A. COMPLETE MILLIVOLT SYSTEM CHECk
(“A” Reading - Thermostat contacts CLOSED - Control knob “ON” - Main burner

should turn ON)
a. If the reading is more than 100 millivolts and the automatic valve still does not come on,

replace the control.

b. If the closed circuit reading (“A” reading) is less than 100 millivolts, determine cause for

low reading, proceed to Section B below.

B. Thermopile Output Reading Check

(“B” Reading - Thermostat contacts OPEN - Main burner OFF)
1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data

plate, then check pilot voltage, 35 millivolts minimum. If the minimum millivolt reading is
not obtainable, replace pilot.

Connect Meter

Switch or

Meter

Check

To

Leads to

Thermostat

Reading

Test

Test

Terminals

Contacts

Should Be

A

Complete

 & 3

Closed

Closed

System

B

Thermopile

1 & 

Open

Open

Advertising