LOG PLACEMENT

Before you begin — This unit is supplied with six (6) ceramic fiber logs. Do not handle
these logs with your bare hands. Always wear gloves to prevent skin irritation from
ceramic fibers.
After handling the logs, wash your hands gently with soap and water to
remove any traces of fibers.

W

ARNING

The positioning of the logs is critical to the safe and clean operation of
this heater. Sooting and other problems may result if the logs are not
properly and firmly positioned in the appliance. Never add additional
logs or embellishments such as pine cones, vermiculite or rock wool
to the heater. Only use the logs and TPB-RW (rock wool) supplied with
the unit.
Failure to position the parts in accordance with diagrams below or
to use only parts specifically approved for this heater may result in
property damage or personal injury.

CAUTION

DO NOT sprinkle volcanic rock on the logs or around the pilot or the
main burner. This may cause sooting. Only place volcanic rock on the
floor of the fireplace.
During initial operation of the new heater, burning logs will give off a
paper burning smell and orange flames will be present. Simply open
the windows for a few hours to vent the odor.

DFX24C LOG PLACEMENT

Figure 19
1. Install the rear log (#3) on back of burner.
. Install the right log (#1) on burner pins on right side of

burner.

3. Install the left log (#) on burner pins on left side of

burner.

LG699
24VFSC logs

Left Log
#

Right Log #1

Rear Log #3

LG699

Figure 19 -
DFX24C Log Placement

Burner
Pins

Burner
Pins