PERFORMANCE DATA HEAT operation

CAPACITY:5.8(kW)

INPUT:1700(W)

OUTDOOR WB(

:

)

INDOOR

-10

-5

0

5

10

15

20

DB(

:

)

Q

INPUT

Q

INPUT

Q

INPUT

Q

INPUT

Q

INPUT

Q

INPUT

Q

INPUT

15
21
26

3.65

1105

4.41

1326

5.16

1496

5.92

1615

6.67

1717

7.37

1768

8.12

1802

3.48

1190

4.18

1411

4.93

1564

5.63

1683

6.38

1768

7.08

1819

7.80

1887

3.13

1275

3.89

1496

4.58

1649

5.34

1768

6.09

1853

6.79

1904

7.54

1955

MSZ-GB50VA : MUZ-GB50VA

Rated frequency 75Hz

ACTUATOR CONTROL

9

MUZ-GB50VA

9-2. R.V. coil control

Heating . . . . . . . . . . . . . . . . ON
Cooling. . . . . . . . . . . . . . . . . OFF
Dry . . . . . . . . . . . . . . . . . . . . OFF

NOTE: The 4-way valve reverses for 5 seconds right before start-up of the compressor.

ON

OFF

ON

OFF

Outdoor fan

motor

Compressor

5 seconds

15 seconds

ON

OFF

Compressor

Outdoor fan

motor

ON

OFF

<COOL>

5 seconds

<HEAT>

5 seconds

R.V.coil

ON

OFF

ON or OFF

ON or OFF

9-1. Outdoor fan motor control

The fan motor turns ON/OFF, interlocking with the compressor.
[ON] The fan motor turns ON 5 seconds before the compressor starts up.
[OFF] The fan motor turns OFF 15 seconds after the compressor has stopped running.

NOTE Q : Total capacity (kW) INPUT : Total power input (W) DB : Dry-bulb temperature WB : Wet-bulb temperature