MITSUBISHI ELECTRIC MUZ-GB50VA User Manual

Page 22

Advertising
background image

22

Primary current protection

Secondary current protection

High-pressure protection

Defrosting in cooling

3 times

Lighting

Discharge temperature
protection

Check refrigerant circuit and refrigerant amount.

Refer to 10-6.

G

"Check of LEV".

Refer to 10-6.

B

"Check of outdoor thermistors".

4 times

Lighting

Low discharge
temperature protection

Refer to 10-6.

G

"Check of LEV".

Check refrigerant circuit and refrigerant amount.

5 times

Lighting

Cooling high-pressure
protection

This symptom does not mean any abnormality of the
product, but check the following points.

Check if indoor filters are clogged.

Check if refrigerant is short.

Check if indoor/outdoor unit air circulation is short cycled.

-

-

These symptoms do not mean any abnormality of the
product, but check the following points.

Check if indoor filters are clogged.

Check if refrigerant is short.

Check if indoor/outdoor unit air circulation is short cycled.

Twice

Lighting

Once

Lighting

When the discharge temperature exceeds 100

:

during operation.

When the frequency of the compressor is kept 80Hz or more and
the discharge temperature is kept under 39

:

for more than 20

minutes.

When the outdoor heat exchanger temperature exceeds 58

:

during operation.

9 times

Lighting

Inverter check mode

Lighting

Lighting

Normal

When the unit is operated with emergency operation switch.

-

When the input current exceeds 15A.

When the current of the compressor exceeds 15A.

When the indoor gas pipe temperature exceeds 45

:

during heating.

When the indoor gas pipe temperature falls 3

:

or below during cooling.

LED1(Red) LED2(Yellow)

Abnormal point / Condition

Correspondence

Indication

Condition

Outdoor unit
operates.

Outdoor unit
operates

No. Symptom

20

21

22

23

24

25

26

OB455A--1qxq 06.7.31 2:19 PM Page 22