Disassembly instructions 11 – MITSUBISHI ELECTRIC MUZ-GB50VA User Manual

Page 34

Advertising
background image

34

DISASSEMBLY INSTRUCTIONS

11

(1) Slide the sleeve and check if there is a locking lever or not.

(2) The terminal with this connector has the
locking mechanism.

1

Slide the sleeve.

2

Pull the terminal while

pushing the locking
lever.

1

Hold the sleeve, and

pull out the terminal
slowly.

The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.

<"Terminal with locking mechanism" Detaching points>

Connector

Sleeve

Locking lever

MUZ-GB50VA

OUTDOOR UNIT

OPERATING PROCEDURE

PHOTOS

1. Removing the cabinet

(1) Remove the screws of the service panel.
(2) Remove the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove the top panel.
(6) Remove the valve cover.
(7) Remove the screws of the cabinet.
(8) Remove the cabinet.
(9) Remove the screws of the back panel.
(10) Remove the back panel.

Photo 2

Photo 1

Photo 3

Screw of the top panel

Screws of the cabinet

Screws
of the
cabinet

Screws
of the
top
panel

Screw of the motor support

Set screws of the back panel

Screws
of the
cabinet

Screw of the service panel

Screw
of the
valve
cover

Screws
of the
back
panel

OB455 A--2qxp 06.7.31 2:50 PM Page 34

Advertising