Muz-gb50va – MITSUBISHI ELECTRIC MUZ-GB50VA User Manual

Page 23

Advertising
background image

23

Part name

Figure

Check method and criterion

Defrost thermistor
(RT61)

Ambient temperature
thermistor (RT65)

Outdoor heat exchanger
temperature thermistor
(RT68)

Normal

2.6k

"

~ 3.3k

"

Normal

0.40

"

~ 0.49

"

Discharge temperature
thermistor (RT62)

Fin temperature
thermistor (RT64)

Measure the resistance between terminals using a tester.
(Winding temperature : -10°C ~ 40°C)

Compressor

W

U

V

WHT

RED

BLK

Measure the resistance between lead wires using a tester.
(Part temperature : -10°C ~ 40°C)

Outdoor fan motor

Measure the resistance using a tester. (Part temperature : -10°C ~ 40°C)

R. V. coil

Measure the resistance using a tester.(Part temperature : -10°C ~ 40°C)

Linear expansion valve

LEV

WHT

RED

YLW BRN

ORN

BLU

Color of lead wire

Normal

WHT - RED
RED - ORN

YLW - BRN

BRN - BLU

37.4

"

~ 53.9

"

MUZ-GB50VA

U

RED

WHT

BLK

V

W

(W)

(V)

(U)

Normal

RED - BLK

BLK - WHT

WHT - RED

13.4

"

~ 16.4

"

Color of lead wire

Measure the resistance with a tester.

Refer to 10-7. “Test point diagram and voltage”,1. “Outdoor electronic
control P.C. board”, the chart of thermistor.

Measure the resistance with a tester.
Before measurement, hold the thermistor with your hands to warm it up.

Refer to 10-7. “Test point diagram and voltage”,1. “Outdoor electronic
control P.C. board”, the chart of thermistor.

10-5. Trouble criterion of main parts

OB455A--1qxq 06.7.31 2:19 PM Page 23

Advertising