7. connecting work clamp and gas/air supply – Miller Electric Spectrum 1250R User Manual

Page 20

Advertising
background image

OM-217 Page 16

3-7.

Connecting Work Clamp And Gas/Air Supply

ST-800 958 / ST-800 701 / S-0818

1

Work Cable

Connect work cable to supplied
clamp as shown.

Connect work clamp to a clean lo-
cation on workpiece, as close to
cutting area as possible.

.

Use only clean, dry air or nitro-
gen gas. Do not use any other
gas or combination of gases.

2

Air Filter/Regulator

3

Gas/Air Inlet Opening

4

Hose

5

Teflon Tape

Obtain hose with 5/8-18 right-hand
thread fitting. Wrap threads with
teflon tape, and install fitting in
opening.

Adjust gas/air pressure according
to Section 4-1.

Tools Needed:

5/8, 1-1/8 in

From Gas/Air Supply

1

3

2

4

5

Advertising