OM-217 Page 23

5-3.

Overload Protection: Trouble Lights & Checking Shield Cup Shutdown System

If certain problems occur, the
Ready light goes off, a trouble light
comes on, and output stops.

1

Gas/Air Or Shield Cup Light

Lights if low gas/air pressure oc-
curs, if shield cup is loose, or if o-
ring is defective.

Turn power Off, and check shield
cup connection (see torch Owner’s
Manual). Check for proper gas/air
pressure (see Section 4-1).

Check shield cup shutdown system
once a week as shown.

2

Torch-To-Tip Short Light

Lights if a short exists between tip
and electrode. Check tip and elec-
trode (see torch Owner’s Manual).

3

Temperature Light

Lights if power source overheats
(see Section 3-2).

4

Torch Shield Cup

Turn Power On and loosen shield
cup. If shutdown system works
properly, Ready light goes off and
Gas/Air Or Shield Cup light comes
on. If not, turn power Off and check
for proper gas/air pressure (see
Section 4-1), blocked or leaking
hose, or loose shield cup (see torch
Owner’s Manual).

If system works properly, retighten
cup and turn Off power.

Ref. ST-800 713

1

2

3

Checking Torch Shield Cup Shutdown System

4

Advertising