Trouble

Remedy

Temperature Trouble light on; Ready
light off.

Thermostat TP1 and/or TP2 open (overheating). Allow fan to run; the thermostat closes when the unit has
cooled (see Section 3-2).

Have Factory Authorized Service Agent check timer/control board PC1.

No high gas/air flow (cutting air), or de-
creased cutting ability.

Check for sufficient gas/air supply pressure and correct gas/air pressure adjustment (see Section 4-1).

Have Factory Authorized Service Agent check reed switch RS1, high air solenoid AS2, and air circuitry.

Fan motor FM does not run; Power light
and Ready light both on.

Check fan motor connections.

Trouble lights not working.

Have Factory Authorized Service Agent check indicator board PC3 and timer/control board PC1.

Power light on; Trouble lights on; cutting
output available.

Have Factory Authorized Service Agent check timer/control board PC1.