Setting the temperature system, Displaying the power system statistics – Motorola CAJUN P880 User Manual

Page 80

Advertising
background image

2 - 46

Cajun P880 Routing Switch Installation Guide

2

Setting the Temperature System

You can set the upper and lower temperature warning systems for
your switch’s backplane and slot 1.

To configure the temperature warning systems:

1. In the System Information section of the Web Agent window,

click

Temperature. The Temperature System dialog box opens.

2. Enter the desired temperature warnings for the switch

backplane and slot 1 sensors, and enter the desired
temperature

warning for the CPU sensor.

3. Click on APPLY to save your changes, or Defaults to restore the

temperature defaults.

* Note: The supervisor modules shut down the switching

modules if the temperature reaches the Shutdown
temperature. The modules are restarted if the
temperature goes below the Upper Warning
Temperature. The default Shutdown temperature for the
slot 1 sensor and backplane sensor is 50° C. You can set
the warning temperature to a value lower than 50° C to
ensure prompt notification of an over-temperature
situation.

Displaying the Power System Statistics

To display the power system statistics:

1. In the System Information section of the Web Agent window,

click

Power System. The Power System dialog box opens.

2. Use Table26 to review your power system statistics:

Table 26. Power System Statistical Parameters

Parameter

Definition

Power Supply

Indicates the power supply is present.

Status

Identifies if the power supply is working properly.

Type

Describes the type of power supply detected.