Finishing the Zone Keypads

Figure 10—Zone Keypad Wiring

Figure 10 shows the wiring hookups for the backside connectors of the Zone Keypad (XDM46K).

How to read the schematic:

1. The 16-gauge (power) and 18-gauge (for the speakers), 2-conductor wires attach to the 1x6

connector. The wire that provides power from the controller attaches where indicated by the

label on the connector – the solid red indicates the position of the positive wire while the

striped red indicates the position of the negative wire. The position of the speaker +/- L and +/-
R is indicated by the L+, L-, R+ and R- lettering on the label.

2. The 1x10 connector attaches to the two CAT-5 cables. On the label, a heavy black line separates

the connection of the two wires. Any unused wires are cut off. Refer to the connector label for
the proper position of each color-coded wire. From top to bottom, the color code is as follows:

blue/white, blue, green, orange, brown, and brown/white. This group is for the CAT-5 cable that

goes to the wall plate. The remaining color codes are orange, orange/white, green, and

green/white. This group is for the CAT-5 cable that carries the controller communication data.

How to Make the Connections

• Carefully strip insulation on wires from 3/16 to ¼ inch. Do not strip more than ¼ inch of insulation

off of wire. Strip approximately 1/4 inch of insulation from each wire conductor.

• Attach all wires to their specific location as labeled on the connectors and as shown in the wiring

connection detail.