Rough-In Considerations

• Keep all Expansion Hub wiring away from 120/240V wires, security, dimmers, and other control

wiring.

• Allow enough length on all wires to reach an Expansion Hub located ten feet away from the wall

port.

• Label all CAT-5 wiring: Zone 5, Zone 6, Zone 7, and Zone 8.

• DO NOT confuse the Zone CAT-5 wires with the Door Station CAT-5 wires.

• Knot or fasten all wires in some manner to prevent them from slipping out through the back of the

electrical box located at the wall port.

Wiring Considerations

• Attach the Expansion Hub cable from the Central Controller to the

Expansion Hub.

• Attach the 16-gauge, 2-conductor power wiring to the removable power connector as indicated on

the connector label and as shown in the wiring connection detail.

• Attach the CAT-5 wires to the removable zone connectors as indicated on the connector label and

as shown in the wiring connection detail.

• DO NOT confuse the Zone CAT-5 wires with the Door Station CAT-5 wires.

Wiring the Expansion Hub

Figure 12—Back of the Expansion Hub

Figure 12 shows the wiring hookups for the backside connectors of the Expansion Hub (XDM46EH).

How to read the schematic:

115951B.pdf 25