Portable forced air heaters, Service procedures, Continued – Master Lock B150CEH User Manual

Page 12

Advertising
background image

10

105398

PORTABLE FORCED AIR HEATERS

R

AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS

1.

Remove upper shell (see page 8).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover.

4.

Replace air output and lint filters.

5.

Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 6).

6.

Replace filter end cover.

7.

Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters

PUMP PRESSURE
ADJUSTMENT

1.

Remove pressure gauge plug from filter
end cover.

2.

Install accessory pressure gauge (part
number HA1180).

3.

Start heater (see Operation, page 5).
Allow motor to reach full speed.

4.

Adjust pressure. Turn relief valve to
right to increase pressure. Turn relief
valve to left to decrease pressure. See
specifications below for correct pres-
sure for each model.

5.

Remove pressure gauge. Replace pres-
sure gauge plug in filter end cover.

Figure 13 - Air Output, Air Intake, and Lint Filters, B35CEH and B70CEH Models

Figure 15 - Pressure Gauge Plug Removal

Pressure
Gauge
Plug

Pressure
Gauge

Figure 16 - Adjusting Pump Pressure

Pump
Pressure

Model

(Bar/PSI)

B35CEH

0.200/2.9

B70CEH

0.338/4.9

B100CEH

0.338/4.9

B150CEH

0.380/5.5

(B35CEH and B70CEH Models Shown)

Relief
Valve

SERVICE
PROCEDURES

Continued

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output
Filter

Fan Guard

Air Intake Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 14 - Air Output, Air Intake, and Lint Filters, B100CEH and B150CEH Models

Fan Guard

Plastic Cap

Advertising