Owner’s manual, Troubleshooting – Master Lock B150CEH User Manual

Page 9

Advertising
background image

7

105398

OWNER’S MANUAL

REMEDY

1. Fill tank with kerosene
2. See Pump Pressure Adjustment, page 10
3. See Fuel Filter, page 8
4. See Nozzle Assembly, page 11
5. Drain and flush fuel tank with clean

kerosene. See Storing, Transporting, or
Shipping,
page 6

6. Check electrical connections. See Wiring

Diagram, page 23

7. Replace ignitor, see page 9
8. Replace ignition control assembly

1. See Pump Pressure Adjustment, page 10
2. See Air Output, Air Intake, and Lint

Filters, page 10

3. See Fuel Filter, page 8
4. See Nozzle Assembly, page 11
5. Make sure photocell boot is properly

seated in bracket

6. Clean photocell lens
7. Check electrical connections. See Wiring

Diagram, page 23

8. Replace photocell
9. Replace ignition control assembly

POSSIBLE CAUSE

1. No fuel in tank
2. Pump pressure incorrect
3. Dirty fuel filter
4. Obstruction in nozzle assembly
5. Water in fuel tank

6. Bad electrical connection between

ignitor and ignition control assembly

7. Defective ignitor
8. Defective ignition control assembly

1. Pump pressure incorrect
2. Dirty air intake, air output, and/or lint

filter

3. Dirty fuel filter
4. Obstruction in nozzle assembly
5. Photocell assembly not properly

installed (not seeing the flame)

6. Dirty photocell lens
7. Bad electrical connection between

photocell and ignition control assembly

8. Defective photocell
9. Defective ignition control assembly

TROUBLESHOOTING

Continued

FAULT CONDITION

Motor starts and runs but heater does not
ignite (ON/OFF switch light remains on)

Heater ignites but ignition control assembly
shuts heater off after a short period of time
(ON/OFF switch light remains on)

WARNING: High voltage!

WARNING: High voltage!

HEATER WITH NON-FUSED IGNITION CONTROL ASSEMBLY ONLY

REMEDY

1. Verify that power cord is plugged into

an electrical outlet and that the circuit
breaker in the electral panel is reset

2. Check electrical wiring and connections.

See Wiring Diagram, page 23

3. Check ignitor wiring. If no problems are

found, replace ignitor (see page 9)

1. Check motor wiring. If no problems are

found, replace motor

POSSIBLE CAUSE

1. No power to heater

2. Bad electrical connections

3. Electrical short in ignitor

1. Electrical short in motor

FAULT CONDITION

ON/OFF switch light does not come on
when switch is turned to the ON (|) position
and heater does not start

ON/OFF switch light comes on when switch
is turned to the ON (|) Position but turns off
after five seconds

ATTENTION:

The ignition control has built-in protection against current overloads.

Use the light in the ON/OFF switch to troubleshoot the fault condition.

WARNING: High voltage!

WARNING: High voltage!

Advertising