Portable forced air heaters, Service procedures, Continued – Master Lock B150CEH User Manual

Page 14

Advertising
background image

12

105398

PORTABLE FORCED AIR HEATERS

R

PUMP ROTOR

(Procedure if Rotor is Binding)

1.

Remove upper shell (see page 8).

2.

Remove filter end cover screws using
5/16" nut-driver.

3.

Remove filter end cover and air filters.

4.

Remove pump plate screws using 5/16"
nut-driver.

5.

Remove pump plate.

6.

Remove rotor, insert, and blades.

7.

Check for debris in pump. If debris is
found, blow out with compressed air.

8.

Install insert and rotor.

9.

Check gap on rotor. Adjust to .076/.101
mm (.003"/.004") if needed (see Fig-
ure 25).

Note:

Rotate rotor one full turn to ensure

the gap is .076/.101 mm (.003"/.004") at
tightest position. Adjust if needed.

10. Install blades, pump plate, air filters,

and filter end cover.

11. Replace fan guard and upper shell.

12. Adjust pump pressure (see page 10).

Note:

If rotor is still binding, proceed as

follows.

13. Perform steps 1 through 6 above.

14. Place fine grade sandpaper (600 grit)

on flat surface. Sand rotor lightly in
“figure 8” motion four times (see Fig-
ure 26).

15. Reinstall insert and rotor.

16. Perform steps 10 through 12 above.

Figure 23 - Rotor Location, B35CEH and B70CEH Models

Figure 24 - Rotor Location, B100CEH and B150CEH Models

Insert

Blade

Rotor

Pump
Plate

Air Intake Filter

Air Output
Filter

Pump
Plate

Insert

Rotor

Blade

Filter End
Cover

Air
Intake
Filter

Air Output
Filter

Fan Guard

Fan Guard

Filter End
Cover

Figure 26 - Sanding Rotor

Figure 25 - Gap Adjusting Screw Locations

SERVICE
PROCEDURES

Continued

Gap Adjusting
Screw

Gap Adjusting
Screw

Blade

.076/.101 mm (.003"/.004") Gap
Measured With Feeler Gauge

Rotor

Sandpaper

Advertising
This manual is related to the following products: