8 two-wire serial interface (twsi) ac timing, 1 twsi ac timing table, Table 55 – Marvel Group Integrated Controller 88F6281 User Manual

Page 103: Twsi master ac timing table, Table 56, Twsi slave ac timing table

Advertising
background image

Electrical Specifications

AC Electrical Specifications

Copyright © 2008 Marvell

Doc. No. MV-S104859-U0 Rev. E

December 2, 2008, Preliminary

Document Classification: Proprietary Information

Page 103

8.6.8

Two-Wire Serial Interface (TWSI) AC Timing

8.6.8.1

TWSI AC Timing Table

Table 55: TWSI Master AC Timing Table

Table 56: TWSI Slave AC Timing Table

Description

Sym bol

Min

Max

Units

Notes

SCK clock frequency

fCK

kHz

1

SCK minimum low level w idth

tLOW

0.47

-

tCK

2

SCK minimum high level w idth

tHIGH

0.40

-

tCK

2

SDA input setup time relative to SCK rising edge

tSU

250.0

-

ns

-

SDA input hold time relative to SCK falling edge

tHD

0.0

-

ns

-

SDA and SCK rise time

tr

-

1000.0

ns

2, 3

SDA and SCK fall time

tf

-

300.0

ns

2, 3

SDA output delay relative to SCK falling edge

tOV

0.0

0.4

tCK

2

Notes:

General comment: All values referred to VIH(min) and VIL(max) levels, unless otherw ise specified.

General comment: tCK = 1/fCK.

1. See "Reference Clocks" table for more details.

2. For all signals, the load is CL = 100 pF, and RL value can be 500 ohm to 8 kilohm.

3. Rise time measured from VIL(max) to VIH(min), fall time measured from VIH(min) to VIL(max).

See note 1

Min

Max

SCK minimum low level w idth

tLOW

4.7

-

us

1

SCK minimum high level w idth

tHIGH

4.0

-

us

1

SDA input setup time relative to SCK rising edge

tSU

250.0

-

ns

-

SDA input hold time relative to SCK falling edge

tHD

0.0

-

ns

-

SDA and SCK rise time

tr

-

1000.0

ns

1, 2

SDA and SCK fall time

tf

-

300.0

ns

1, 2

SDA output delay relative to SCK falling edge

tOV

0.0

4.0

us

1

Notes:

General comment: All values referred to VIH(min) and VIL(max) levels, unless otherw ise specified.

1. For all signals, the load is CL = 100 pF, and RL value can be 500 ohm to 8 kilohm.

2. Rise time measured from VIL(max) to VIH(min), fall time measured from VIH(min) to VIL(max).

Notes

100 kHz

Description

Sym bol

Units

Advertising