2 modulation balance attenuation – Motorola PR400 User Manual

Page 38

Advertising
background image

August, 2004

6881096C24-A

5-4

Radio Alignment Procedures: Transmitter Alignment Options

1.

Under Tx Align menu, select Reference Oscillator Warp (

Figure 5-3

).

2.

There is only 1 frequency point shown which is always the last non-0 transmit frequency point,
which will normally be F7.

3.

Click on the slider thumb and press PTT Toggle to key up the radio at the corresponding fre-
quency point.

4.

Monitor the transmit frequency.

5.

Adjust the slider, spin or edit control (press ENTER to confirm selection/send a softpot value) until
the frequency is as close as possible to the indicated transmit frequency. (Refer to

Table 5-2

).

6.

Dekey the radio by pressing PTT Toggle.

7.

Program the warp value into the radio by pressing the Program button.

8.

Exit the Reference Oscillator Warp function.

5.4.2

Modulation Balance Attenuation

Table 5-2. Reference Oscillator Specifications

RF Band

Target

VHF Band 1 (136-162 MHz)

±

162 Hz

VHF Band 2 (146-174 MHz)

±

174 Hz

UHF Band 1 (403-440 MHz)

±

436 Hz

UHF Band 2 (438-470 MHz)

±

470 Hz

UHF Band 3 (465-495 MHz)

±

495 Hz

Note: When using test box RLN4460:

• Inject the signal into the radio via the METER IN terminal and

• Set the METER IN selector switch to "VOL".

• Inject the signal into the radio via the AUDIO IN terminal.

• Set the METER OUT toggle switch to the “MIC PORT” position

• Set the METER OUT selector switch to “MIC”.

Advertising