Various settings (continued), Setup menu, Settings related to communication – MITSUBISHI ELECTRIC DX-TL5716U User Manual

Page 118: Rs-232c setting, Rs-485 cascade setting, Lan setting

Advertising
background image

114

Settings related to communication

<Communication setting>

RS-232C setting

You can remotely control the recorder using a PC connected
to the RS-232C terminal of the recorder.

PC

Recorder

Connection via

RS-232C

Step

1 Select the communication mode.

[Remote A]: The recorder is controlled by a PC and
returns all types of operation status notifi cation.

[Remote B]: The recorder is controlled by a PC and
returns only responses to the command codes.

[Remote C]: The recorder is controlled by a PC and
does not return any notifi cation.

[Off]: The recorder is not controlled by a PC.

Step

2 Set the following items.

Transmission

rate

Data bit length

Parity

bit

Stop bit length

CR/CR•LF (Carriage return and line feed)

Notice

Set these items same as those of the PC to be
connected.

The command code table is contained in the CD
supplied with the recorder.

RS-485 cascade setting

You can make settings for the cascade function used via the
keyboard connected to RS-485 terminal on this recorder.

Step

1 Set the recorder address.

[Off]: The cascade function is not used.

[ID:01] to [ID:16]: When the cascade function is
used, set the ID number of the recorder.

Notice

Set the recorder address uniquely.

LAN setting

The recorder can communicate with a PC connected to its
LAN port.

Connection via

LAN port

Recorder

PC

Step

1 Set the IP address, subnet mask, and gateway.

The MAC address is shown on the screen.

Notice

Do not assign "000.000.000.000" to the IP address
and broadcast address. Otherwise, not only the
communication functions but also the other functions
of the recorder may not operate correctly.

LAN service port settings

Step

1 Select [Setting] next to [LAN service port

settings] on the <LAN setting> screen.

The <LAN service port settings> screen is displayed.

Step

2 Set [COM port] and [SSL port] of the Web, and

[COM port] of the special network software.

Set the port number for connecting to the PC.

Normally, leave the settings as it is.

Notice

If you are unfamiliar with network settings, you are
recommended not to change the settings.

For other communication port settings than [COM
port] and [SSL port] of the Web and [COM port] of the
special network software, use the special PC viewing/
communication software. For the usage, refer to the
instruction manual of the software.

E-mail notifi cation - Address setting

Step

1 Select [Confirm] next to [E-mail notification

settings] on the <LAN setting> screen.

The <E-mail notifi cation - Address setting> screen is

displayed.

Step

2 Check the settings of [Status], [Address setting],

and [Recorder ID].

When you select [Test], test e-mail is sent to the

selected address.

Notice

To set [Recorder ID] and [Address setting], use
the Web function of this recorder or the special PC
viewing/communication software.