Recording (continued) – MITSUBISHI ELECTRIC DX-TL5716U User Manual

Page 60

Advertising
background image

56

Step

7 Set the pre-alarm recording time in [Pre-alarm

time] under [Alarm recording].

[0 Sec]: Pre-alarm recording is not performed.

Note that the actual pre-alarm recording time may

become shorter than the specifi ed time because of
HDD malfunction or other failure.

Notice

Due to the restrictions on data format, the pre-alarm
recording time may vary from the specifi ed time.

When the alarm recording area is allocated by the
partition setting, the alarm recording data and pre-
alarm recording data are saved in the alarm recording
area. To play back the already recorded data, set [Play
device selection] (

page 70) to [HDD (Alarm)].

The picture quality and FPS of the normal recording or
alarm recording being executed are applied to the pre-
alarm recording.

Pre-alarm recording is performed only when the pre-
alarm recording time is set to other than 0 second.

Recording (continued)

When [REC in normal recording mode by MD] is selected

Normal recording Alarm recording Normal recording Alarm recording

EXT

MD-A

MD-B

EXT & MD-A

EXT & MD-B

EXT or MD-A

EXT or MD-B

(MD-A)

(MD-B)

(MD-A during the

terminal is grounding)

(MD-B during the

terminal is grounding)

(MD-A)

(MD-B)

(EXT)

(EXT)

(EXT)

Normal recording

Alarm recording

(EXT)

(EXT)

(EXT)

(button)

(button or MD-A)

(button or MD-B)

(button or MD-A during

the terminal is grounding)

(button or MD-B during

the terminal is grounding)

(button or MD-A)

(button or MD-B)

(EXT)

(EXT)

(EXT)

Input setting

When [REC in alarm recording mode by MD] is selected

Normal recording Alarm recording Normal recording Alarm recording

During manual operation

During timer operation

During timer operation

EXT

MD-A

MD-B

EXT & MD-A

EXT & MD-B

EXT or MD-A

EXT or MD-B

Normal recording

Alarm recording

(EXT)

(MD-A)

(MD-B)

(MD-A during the

terminal is grounding)

(MD-B during the

terminal is grounding)

(EXT or MD-A)

(EXT or MD-B)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(timer)

(EXT)

(MD-A)

(MD-B)

(MD-A during the

terminal is grounding)

(MD-B during the

terminal is grounding)

(EXT or MD-A)

(EXT or MD-B)

(button)

(button)

(button)

(button)

(button)

(button)

(button)

(EXT)

(EXT)

(EXT)

Input setting

During manual operation

During timer operation

During timer operation

(button): Recording starts when the REC/STOP button on the front panel of the recorder is pressed.
(EXT): Normal recording or alarm recording starts when a signal is input to the ALARM IN terminal on the rear panel of the recorder.
(MD): Normal recording or alarm recording starts when motion is detected.
(timer): Normal recording or alarm recording starts according to the timer recording settings.
: Neither normal recording or alarm recording is performed.

When [MD] on the Timer program

screen is set to [ON]

When [MD] on the Timer

program screen is set to [OFF]

When [MD] on the Timer program

screen is set to [ON]

When [MD] on the Timer

program screen is set to [OFF]

Step

8 Set the alarm recording time in [Post-alarm time]

under [Alarm recording].

[Manual]: Alarm recording continues until the
grounding of the ALARM IN terminal ceases.

When the setting is completed, select [Next]. The

<Picture quality and FPS> screen is displayed.

Notice

Ensure that the Pre-alarm time is shorter than the
Post-alarm time.

Picture quality and FPS

Step

9 Set the picture quality and FPS for normal

recording and alarm recording.

Recording is not performed when FPS is set to [---].

The picture quality has 9 levels from L1 to L9, and

L9 is the highest.

Images from cameras of which [Active] box is

selected are recorded. Images from cameras of
which [Active] box is unselected are not recorded.

By using [Ditto], you can copy the settings of the

above row.

When the setting is completed, select [Next]. The

<Alarm camera setting> screen is displayed.

Advertising