Administrator’s Handbook

300

set system heartbeat option { on | off }
protocol [ udp | tcp ]
port-client [ 1 - 65535 ]
ip-server [

ip_address

|

dns_name

]

port-server [ 1 - 65535 ]
url-server ("

server_name

")

number [ 1 – 1073741823 ]
interval (00:00:00:20)
sleep (00:00:30:00)
contact-email ("

string

@

domain_name

")

location ("

string

"):

The hear tbeat setting is used in conjunction with the configuration ser ver to broadcast contact and location
information about your Gateway. You can specify the

protocol, port, IP-, port-, and URL-server.

The

interval setting specifies the broadcast update frequency. Part of sequence control. The interval is

the spacing between hear tbeats, in d:h:m:s.

The

contact-email setting is a quote-enclosed text string giving an email address for the Gateway’s

administrator.

The

location setting is a text string allowing you to specify your geographical or other location, such as

“Secaucus, NJ.”

The

number setting is part of the sequence control. This is the number of heartbeats to send, at each

“inter val”, before sleeping. For example, if this is 20, in the above layout, each hear tbeat sequence will
send out a total 20 hear tbeats, spaced at 30 second inter vals, and then sleep for 30 minutes. So to
have the Gateway send out packets “forever”, this number can be set ver y high. If it is 1440 and the
inter val is 1 minute, say, the hear tbeat will go out ever y minute for 1440 minutes, or one day, before
sleeping.

The

sleep setting is part of sequence control. This is the time to sleep before starting another heart-

beat sequence, in d:h:m:s.

set system ntp

option [ off | on ]:
server-address (north-america.pool.ntp.org)
alt-server-address (pool.ntp.org):
time-zone [ -12 - 12 ]
update-period (60) [ 1 - 65535 ]:

daylight-savings [ off | on ]

Specifies the NTP ser ver address, time zone, and how often the Gateway should check the time from the
NTP ser ver. The NTP

server-address and alt-server-address can be entered as DNS names as well as IP

addresses. NTP time-zone of 0 is GMT time; options are -12 through 12 (+/- 1 hour increments from GMT
time).

update-period specifies how often, in minutes, the Gateway should update the clock. daylight-sav-

ings specifies whether daylight savings time is in effect; it defaults to off.

set system zerotouch option [ on | off ]

Enables or disables the Zero Touch option.